Kaseman Venturi Valve Selection Guide

Kaseman supplies factory-calibrated venturi valves for airflow control.

Available in different control types and configurations, our valves serve a range of airflow control requirements.

 

Download Datasheet​

This guide explains the differences between Kaseman valve types, the functions to consider, and how airflow requirements and operating pressure affect valve selection and sizing.

1. Understand the Valve

Before sizing, determine whether your system requires a mechanical or electronically controlled airflow solution

constant airflow, Kaseman CVA
Mechanical Constant Volume

​Mechanical Constant Volume - CVA / KCV

Mechanically maintains a preset airflow without external power or control signals.

Suitable for applications requiring constant airflow without external control.

Variable Airflow Control - UVA / VVA / SVA/ KMV
Uses an electric actuator to modulate airflow based on control signals.
Suitable for applications requiring adjustable airflow, such as fume hood exhaust or room pressure/airflow tracking or BMS interation.

adjustable airflow, Kaseman UVA
Variable Airflow Control

2. Define Your Requirements

Choose the valve configuration according to the functions required by your application.
Kaseman venturi valve

Standard Configuration

General airflow control

Kaseman shut off venturi valve

Airflow Shutoff Function

For applications requiring airflow to be shut off completely (0 CMH)

Kaseman Low leakage venturi valve

Low Leakage

Function

For applications requiring minimal air leakage across the valve assembly

Kaseman ultra low venturi valve

Ultra-Low Flow Capability

For applications requiring control at very low airflow rates (25 to 125 CMH)

Combining Requirements
Shutoff and low-leakage performance may be required together, depending on the application.

Consult our team to evaluate complex or combined specifications

3. Determine the Size

Valve sizing depends on the required airflow range. Duct diameter or maximum airflow alone is not sufficient to determine the correct valve size.

Minimum Airflow

The lowest airflow the valve must control.

Maximum Airflow

The highest airflow the valve must deliver.

Operating Pressure

The pressure available across the valve during operation.
Kaseman offers low-pressure (75pa-750pa) and mid-pressure (150pa-750pa)venturi valves for different operating conditions.

4. Selection Support

Kaseman supports venturi valve projects worldwide.

Contact our team to discuss your project requirements and explore a suitable airflow control solution.

You can also define these additional configuration options:

Kaseman VVA

Application

Kaseman venturi valve

Coating Options

Kaseman VVA

Fail-Safe Function

Kaseman VVA

Power Supply Options